CONTROLLED • TRANSPARENT • PRIVATE
Diagnose what the browser actually observes.
Test buttons, switches, wheel behaviour, movement timing and repeatability. Results are labelled by evidence type and never silently presented as hardware-level measurements.
Session
Scroll-wheel diagnostics
Scroll inside the capture surface. Page scrolling is suppressed there.
Direction sequence
Path & movement
Movement is captured only inside this zone. Raw paths are excluded from report exports by default.
Browser-observed polling rate
Move continuously in small circles during collection.
Interval distribution
Stationary jitter & drift
Place the pointer over the zone and do not touch the mouse.
Drag reliability
Hold the left button and drag the marker from START to FINISH without releasing.
Target acquisition
Measures the combined user-mouse-display system, not hardware alone.
DPI calibration
Premise correction: a browser cannot read configured hardware DPI. This module estimates counts per inch from a manually measured physical movement.
Curve receptivity
A stream of notes along a curved path, in the spirit of a fast rhythm-game "stream" (~250 BPM). Click each note as it lights up while keeping the cursor hugging the curve in between. Tracking accuracy is measured continuously, not just the clicks.
Ready
An aim/perception benchmark, not a hardware fault check. It does not feed the Health score.
Event inspector
Bounded live recorder. Coordinates can be excluded from exports.
| # | Time | Type | Button | Buttons | X,Y | ΔX,ΔY | Pointer | Trusted |
|---|
Health & evidence-based diagnosis
Findings
Published weighting
Button 30%, wheel 20%, movement 20%, timing 20%, drag 10%. Unavailable components are omitted and weights renormalised. Performance targets do not lower health merely because a device is intentionally low-rate.
Reports & evidence
Export
Import
Session summary
Methodology & limitations
Measurement labels
- Direct browser observation: delivered event/property.
- Calculated: arithmetic over observations.
- Estimated: browser-level proxy, e.g. polling.
- Manually calibrated: depends on physical input.
- Inferred: evidence-supported diagnostic hypothesis.
- Unavailable: not exposed by the browser.
Hard limits
- Physical click latency and actuation point are unavailable.
- Hardware DPI is unavailable without calibration.
- Browser rate is after USB, OS and browser processing.
- Trackpads and mice are not always distinguishable.
- Vendor-consumed buttons may never reach the page.
- Raw HID evidence needs a native or permissioned companion.
Privacy
All processing is local. This build contains no analytics, trackers or network calls. Data is not retained unless local history is explicitly enabled. Detailed paths and screen coordinates are excluded from exports by default.